沙特标准、计量和质量组织(SASO)于2023年11月17日发布的《电磁兼容性技术法规》于2024年5月17日正式执行。

法规旨在规定设备电磁兼容性的标准要求并确定供应商应遵守的合格评定程序,确保产品符合保护用户环境、健康和安全的基本要求,并促进市场监督程序。根据合格评定程序,沙特进口商在Saber平台申请清关证书PCOC和SCOC时,应提供供应商合格声明EMC测试报告以证明产品满足技术法规。

该技术法规适用于附录Annex I所列的标准定义相关术语的设备(请参考下图法规原文):

Annex I
Sr.Title of Standard in EnglishStandard No.
1Rotating electrical machines-Part 1: Rating and performanceSASO IEC 60034-1
2Safety of machinery – Electrical equipment of machines – Part 31: Particular safety and EMC requirements for sewing machines, units and systemsSASO IEC 60204-31
3Measuring relays and protection equipment – Part 26: Electromagnetic compatibility requirementSASO GSO IEC 60255-26
4Switches for household and similar fixed electrical installations – Part 2-1: Particular requirements – Electronic switchesSASO IEC 60669-2-1
5Automatic electrical controls- Part 1: General requirementsSASO GSO IEC 60730-1
6Automatic electrical controls- Part 2-5: Particular requirements for automatic electrical burner control systemsSASO GSO IEC 60730-2-5
7Automatic electrical controls- Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirementsSASO GSO IEC 60730-2-6
8Automatic electrical controls- Part 2-7: Particular requirements for timers and time switchesSASO GSO IEC 60730-2-7
9Automatic electrical controls- Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirementsSASO GSO IEC 60730-2-8
10Automatic electrical controls- Part 2-9: Particular requirements for temperature sensing controlSASO GSO IEC 60730-2-9
11Automatic electrical controls- Part 2-14: Particular requirements for electric actuatorsSASO GSO IEC 60730-2-14
12Automatic electrical controls- Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controlsSASO GSO IEC 60730-2-15
13Telecontrol equipment and systems – Part 2: Operating conditions – Section 1: Power supply and electromagnetic compatibilitySASO GSO IEC 60870-2-1
14Low-voltage switchgear and controlgear – Part 1: General rulesSASO GSO IEC 60947-1
15Low-voltage switchgear and controlgear – Part 2: Circuit- breakersSASO GSO IEC 60947-2
16low-voltage switchgear and controlgear – Part 3: Switches, disconnectors, switchdisconnectors and fusecombination unitsSASO GSO IEC 60947-3
17Low-voltage switchgear and controlgear – Part 4-1: Contactors and motor-starters – Electromechanical contactors and motor startersSASO IEC 60947-4-1
18Low-voltage switchgear and controlgear – Part 4-2: Contactors and motor-starters – AC semiconductor motor controllers and startersSASO IEC 60947-4-2
19low-voltage switchgear and controlgear – Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loadsSASO IEC 60947-4-3
20Low-voltage switchgear and controlgear – Part 5-1: Control circuit devices and switching elements – Electromechanical control circuit devicesSASO IEC 60947-5-1
21low-voltage switchgear and controlgear – Part 5-2: Control circuit devices and switching elements – Proximity switchesSASO IEC 60947-5-2
22Low-voltage switchgear and controlgear – Part 5-3: Control circuit devices and switching elements – Requirements for proximity devices with defined behaviour under fault conditions (PDDB)SASO IEC 60947-5-3
23Low-voltage switchgear and controlgear – Part 5-6: Control circuit devices and switching elements – DC interface for proximity sensors and switching amplifiers (NAMUR)SASO IEC 60947-5-6
24Low-voltage switchgear and controlgear – Part 5-7: Control circuit devices and switching elements – Requirements for proximity devices with analogue outputSASO IEC 60947-5-7
25Low-voltage switchgear and controlgear – Part 5-9: Control circuit devices and switching elements – Flow rate switchesSASO IEC 60947-5-9
26Low-voltage switchgear and controlgear – Part 6-1: Multiple function equipment – Transfer switching equipmentSASO IEC 60947-6-1
27Low-voltage switchgear and controlgear – Part 6-2: Multiple function equipment-Control and protective switching devices (or equipment) (CPS)SASO IEC 60947-6-2
28Low-voltage switchgear and controlgear – Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machinesSASO IEC 60947-8
29Low-voltage switchgear and controlgear – Part 9-1: Active arc- fault mitigation systems – Arc quenching devicesIEC 60947-9-1
30Arc welding equipment – Part 10: Electromagnetic compatibility (EMC) requirementsSASO IEC 60974-10
31Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current < 16 A per phase)SASO GSO IEC 61000-3-2
32Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connectionSASO IEC 61000-3-3
33Electromagnetic compatibility (EMC) – Part 3-11: Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems – Equipment with rated current <= 75 A and subject to conditional connectionSASO IEC 61000-3-11
34Electromagnetic compatibility (EMC) – Part 3-12: Limits – Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <=75 A per phaseSASO IEC 61000-3-12
35Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity for residential, commercial and light- industrial environmentsSASO IEC 61000-6-1
36Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environmentsSASO IEC 61000-6-2
37Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standard for equipment in residential environmentsIEC 61000-6-3
38Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environmentsSASO IEC 61000-6-4
39Electromagnetic compatibility (EMC) – Part 6-5: Generic standards – Immunity for equipment used in power station and substation environmentSASO IEC 61000-6-5
40Residual current operated circuit- breakers without integral overcurrent protection for household and similar uses (RCCBs) – Part 1: General rulesSASO IEC 61008-1
41Residual current operated circuit- breakers with integral overcurrent protection for household and similar uses (RCBOs) – Part 1: General rulesSASO IEC 61009-1
42Switches for appliances – Part 1: General requirementsSASO IEC 61058-1
43Industrial-process measurement and control – Programmable controllers – Part 2: Equipment requirements and testsIEC 61131-2
44Low-voltage switch mode power supplies – Part 3: Electromagnetic compatibility (EMC)SASO IEC 61204-3
45Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirementsSASO IEC 61326-1
46Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 2-1: Particular requirements – Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applicationsSASO IEC 61326-2-1
47Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 2-2: Particular requirements – Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systemsSASO IEC 61326-2-2
48Electrical equipment for measurement, control and laboratory use- use – EMC requirements – Part 2-3: Particular requirements – Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioningSASO IEC 61326-2-3
49Low-voltage switchgear and controlgear assemblies – Part 1: General rulesSASO IEC 61439-1
50Low-voltage switchgear and controlgear assemblies – Part 2: Power switchgear and controlgear assembliesSASO IEC 61439-2
51Low-voltage switchgear and controlgear assemblies – Part 3: Distribution boards intended to be operated by ordinary persons (DBO)SASO IEC 61439-3
52Low-voltage switchgear and controlgear assemblies – Part 4: Particular requirements for assemblies for construction sites (ACS)IEC 61439-4
53Low-voltage switchgear and controlgear assemblies – Part 5: Assemblies for power distribution in public networksSASO IEC 61439-5
54Low-voltage switchgear and controlgear assemblies – Part 6: Busbar trunking systems (busways)SASO GSO IEC 61439-6
55Residual current-operated protective devices (RCDs) for household and similar use- Electromagnetic compatibilitySASO IEC 61543
56Equipment for general lighting purposes – EMC immunity requirementsSASO IEC 61547
57Electrical safety in low voltage distribution systems up to 1 000 Va.c. and 1 500 V d.c.- Equipment for testing, measuring or monitoring of protective measures – Part 12: Performance measuring and monitoring devices (PMD)SASO IEC 61557-12
58Electrical accessories – Residual current monitors for household and similar uses (RCMs)SASO IEC 62020
59Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) – Part 1: General rulesSASO IEC 62026-1
60Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) – Part 2: Actuator sensor interface (AS-i)SASO IEC 62026-2
61Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) – Part 3: DeviceNetSASO IEC 62026-3
62Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) – Part 7: CompoNeSASO IEC 62026-7
63Uninterruptible power systems (UPS) – Part 2: Electromagnetic compatibility (EMC) requirementsSASO IEC 62040-2
64Electricity metering equipment (a.c.) – General requirements, tests and test conditions – Part 21: Tariff and load control equipmentSASO IEC 62052-21
65Electricity metering equipment (a.c.)- Particular requirements- Part 11: Electromechanical meters for active energy (classes 0,5, 1and 2)SASO IEC 62053-11
66Electricity metering equipment- Particular requirements – Part 21: Static meters for AC active energy (classes 0,5, 1 and 2)IEC 62053-21
67Electricity metering equipment- Particular requirements – Part 22: Static meters for AC active energy (classes 0,15, 0,25 and 0,55)SASO IEC 62053-22
68Electricity metering equipment – Particular requirements – Part 23: Static meters for reactive energy (classes 2 and 3)SASO IEC 62053-23
69Electricity metering (a.c.)-Tariff and load control – Part 11: Particular requirements for electronic ripple control receiversSASO IEC 62054-11
70Electricity metering (a.c.) – Tariff and load control – Part 21: Particular requirements for time switchesSASO IEC 62054-21
71Resistance welding equipment – Part 2: Electromagnetic compatibility (EMC) requirementsSASO IEC 62135-2
72Static transfer systems (STS) – Part 2: Electromagnetic compatibility (EMC) requirementsSASO IEC 62310-2
73Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar usesSASO IEC 62423
74Power quality measurement in power supply systems – Part 1: Power quality instruments (PQI)SASO IEC 62586-1
75Power quality measurement in power supply systems – Part 2: Functional tests and uncertainty requirementsSASO IEC 62586-2
76General requirements for arc fault detection and protection devices (AFDDs)SASO IEC 62606
77Requirements for automatic reclosing devices (ARDS) for circuit-breakers, RCBOs and RCCBs for household and similar usesSASO GSO IEC 63024
78Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurementSASO CISPR 11
79Vehicles, boats and internal combustion engines – Radio disturbance characteristics- Limits and methods of measurement for the protection of off-board receiversSASO CISPR 12
80Electromagnetic compatibility – Requirements for household appliances, electric tools and similar apparatus – Part 1: EmissionSASO CISPR 14-1
81Electromagnetic compatibility- Requirements for household appliances, electric tools and similar apparatus – Part 2: Immunity – Product family standardSASO CISPR 14-2
82Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentSASO CISPR 15
83Electromagnetic compatibility of multimedia equipment -Emission requirementsSASO CISPR 32
84Electromechanical elementary relays – Part 1: General and safety requirementsSASO IEC 61810-1

下列设备属于法规豁免范围:

  • 无线电设备和电信终端设备
  • 航空航天产品及其零部件
  • 业余爱好者使用的通讯设备
  • 医疗设备
  • 具有以下物理特性的设备
    1. 不能产生或促成电磁发射的设备,其电磁发射超过允许无线电和电信设备及其他设备按预期工作的水平。
    2. 正常使用时不受电磁干扰影响的设备
  • 为专家设计并直接用于研究和开发为目的的电子面板

相关新闻

联系我们

联系我们

130-2794-8025

在线咨询:点击这里给我发消息

邮件:iecee@qq.com

工作时间:周一至周五,9:30-18:30,节假日休息

关注微信
关注微信
分享本页